OpenELIS Global 3.2.3.0 (September 2026)

OpenELIS Global 3.2.3.0 (September 2026)

Version: 3.2.3.0 · Released: 25 September 2026

GitHub release: 3.2.3.0 · Full changelog: 3.2.2.0 → 3.2.3.0

This release brings several new modules to OpenELIS: Microbiology, Quality Assurance and a shared Reporting engine. It also redesigns Validation around a triage queue with guarded bulk release, and moves analyzer setup onto the Analyzer Bridge with guided setup and safe result traffic. Inventory now shares the sample storage system, programmes gain domains and a questionnaire builder, the whole test catalog can be carried and imported as CSV, the FHIR facade answers every search from the OpenELIS database, and patient search tolerates misspelled names. Databases on 3.2.2.0 upgrade in place, with existing analyzers migrated automatically.

Highlights

  • Validation triage (OGC-817). A triage queue with "Check before release" signals, a review panel with per-row actions and history, guarded "Release all clear" bulk release, and reject via NCE or send for retest.

  • Microbiology (OGC-782). A bacteriology workflow covering order entry, culture and AST work, reference administration, WHONET export and surveillance.

  • Quality Assurance module (OGC-688). A QA menu and overview, a Quality Indicators dashboard, statistical QC hardening, QMS registers (Electronic Signature Log, CAPA) and a per-test Accreditation register.

  • Reporting engine. Configurable report sources, shared saved report definitions, queued delivery with retry and retention, and audited exports for results, referrals and non-conformance.

  • Analyzer Bridge setup (OGC-1054). Analyzer Types backed by the Analyzer Bridge, safe test mapping, guided setup and activation, analyzer profile authoring and clearer connection diagnostics.

New features

Validation triage and bulk release (OGC-817)

  • Triage queue: "Check before release" signals, filters and fail-safe lanes (#4172, OGC-1027).

  • Review panel with per-row actions, history and notes (#4185, OGC-1028).

  • Guarded "Release all clear" bulk release, with the Clear lane computed on the server (#4187, OGC-1029).

  • Reject via NCE, send for retest, a stale-page guard and an auto-validated view (#4188, OGC-1030).

  • Ordinary results can now clear for bulk release, and the page says why when a result cannot (#4355, OGC-1226).

Microbiology (OGC-782)

  • Feature and engineering specifications (#3782) and the initial bacteriology MVP (#4136).

  • Clinical depth, reference administration and WHONET (#3984).

  • Workflow alignment and surveillance improvements (#4124), with order-entry remediation and final corrections (#4196).

Quality Assurance (OGC-688)

A top-level QA menu with a QA Overview landing page, a Quality Indicators dashboard with computed indicators and threshold-driven NCE automation, statistical QC hardening on the existing QC module, QMS surfaces (Electronic Signature Log, CAPA Register), a per-test Accreditation register, and the permission model that gates them (#4069). The QC page title is now a real heading for screen readers (#4354, OGC-1224).

Reporting engine

  • Export contracts, persistence and audit (#4304).

  • Configured sample result exports that keep repeat results (#4307), configurable reporting sources and shared saved report definitions (#4308).

  • Queued report delivery with retry, cancellation and retention (#4309).

  • Referrals (#4310) and Non-Conformance (#4318) exported through the shared engine.

  • New report views and routed report state (#4312), connected end to end from report creation to shared reuse and queued delivery (#4314).

Analyzers on the Analyzer Bridge (OGC-1054)

  • Roadmap, CI boundary, acceptance foundation and a clean analyzer profile boundary (#4049, #4053, #4055).

  • Bridge-backed Analyzer Types (#4056), safe Analyzer Type mapping (#4118), and guided analyzer setup and activation (#4125).

  • Safe analyzer result traffic (#4138), with protection against replaying a normalized delivery (#4241).

  • Analyzer profile authoring and clearer connection diagnostics (#4425).

  • Setup can proceed with partial mappings: unambiguous defaults are restored, unresolved rows can be confirmed, and affected results are held for correction and reprocessed once mappings are fixed (#4433).

Inventory

  • A readable code on each inventory item, shown in the catalog and item form (#4015, #4018).

  • Inventory lots stored in the same storage system samples use, with capacity, hierarchy and barcodes (#4016); lots listed beside samples, a disposed lot frees its box, and six navigation rows fold into one page (#4033).

  • An inventory Reports tab with CSV, PDF and XLSX export (#4017).

  • A findable lot barcode (#4026) and fixes to stock visibility, barcodes and item codes (#4019).

Programmes and questionnaires

  • Programs admin: each programme carries a domain (Clinical, Environmental or Vector), an active/inactive lifecycle, any number of lab units, and a visual questionnaire builder with a JSON option (#3979, OGC-781). Order entry offers only active programmes of the order's own domain.

  • Programme questionnaires and their answers are stored in OpenELIS; the external FHIR store is now optional and mirrored when configured (#3622, #4205).

Test catalog

  • A catalog row with several specimens loads as one test linked to all of them, and loads again on every restart without creating duplicates (#4327, OGC-1193).

  • The whole test catalog can be carried in CSV (result components, limits, terminology, sample handling and reflex rules) and imported from Admin → Import Catalog (CSV) with a preview; names the files cannot resolve are queued for a decision rather than logged (#4329, OGC-1194).

  • Test Catalog v2.5 child items closed (#4303, OGC-1118, 1119, 1120, 1121, 1148).

  • Each panel is filed under its own domain, with a warning when its specimens fall outside it (#4334, OGC-1209); operators can create and correct Environmental and Vector panels (#4384, OGC-1232).

  • Test catalog search waits for two characters before searching (#4299, OGC-1134).

FHIR

  • Every FHIR facade search (Patient, Organization, Specimen, ServiceRequest, Observation, DiagnosticReport, Device, Location and Practitioner) is answered from the OpenELIS database, with _id, _lastUpdated and the supported _include/_revinclude pairs (#4223). Every declared search parameter works and paging is correct (#4235).

  • New facade providers and search: Practitioner (#3720), DiagnosticReport (#3555), Device (#3560) and storage Location (#3563), with Observation carrying its performer (#3675) and provider-specific transformation services (#3595).

  • Explicitly selected samples can be replayed through the native transforms (#4323).

Other features

  • Unified Results worklist on by default, with a new "Search by patient" option (#4209); a live range flag, sample kind and eOrder lab-unit scope on results (#4405).

  • Patient search matches misspelled names and is much faster (#4227).

  • Lab Unit Management: a unified list and editor (#4121, OGC-189).

  • Anatomic pathology: a shared case-view shell for the pathology screens (#4321, OGC-1195), and bench stages replacing the legacy pathology status values, each optional stage switchable per deployment (#4298, OGC-264).

  • Batch workplans: pending tests and batches on a new Workplan page (#3814, OGC-427).

  • Provider titles, chosen from a list an administrator keeps (#4339, OGC-1223).

  • Numeric results accept Unicode superscript exponents, for example 1.5 x 10⁵ (#4380).

  • Configurable navigation with sections, icons and report routes (#4315).

  • Cold storage monitoring: an offline freezer now raises its own alert and clears it when the device answers again, and every cold-storage and alert endpoint is permission-checked (#3828).

  • Screens refresh their data in place after a save instead of reloading the whole page (#4213).

  • SILNAS demo changes synced into develop (#3946).

Improvements & bug fixes

  • Order entry and Edit Order. Edit Order no longer silently reassigns a specimen's accession (#4156, OGC-1191) and cancels every analysis on a removed sample item (#4326, OGC-1221); panels no longer bring in tests not configured for the sample type (#4159, OGC-1189); environmental orders without a patient reach the dashboard (#4203, OGC-1192); order entry keeps working when a Program row is deleted (#4335, OGC-1222); a consolidated set of order-entry fixes (#4282, OGC-1201).

  • Results. Titer results get an entry control (#4293, OGC-1185); multi-select results are filed on the component they were entered on (#4294, OGC-1186); batch test reassignment works again (#4296, OGC-1187); status filter chips are spaced below the toolbar (#4233).

  • Validation. Switching validation submenus loads the right page (#4301), and the result value stays on one line beside its flag (#4426).

  • Referrals. A refer-out from Results Entry reaches the reference lab (#4242, OGC-1188); the Reference Lab Results page shows outstanding referrals accurately (#4267); critical-result alerts name the patient and range, and the reject reason length is enforced (#4325, OGC-803, OGC-804).

  • Reports. Referred tests are no longer counted as the laboratory's own work (#4375); an incomplete report link says what it is missing (#4297, OGC-1053).

  • Test catalog editor. A duplicate test description answers with a clear conflict instead of a server error (#4126, OGC-1180); a refused catalog import is reported (#4352, OGC-1228); editor actions and section saves keep data, take effect and report what actually happened (#4415, OGC-1234; #4420, OGC-1238); sample types are labelled by name (#4402).

  • User management. Modify User shows the right lab unit and refuses All Lab Units next to scoped grants (#4378, OGC-1231).

  • Shipments. Every sample staged for a box is kept (#4266).

  • Analyzers. Setup and deployment fixes, mapping state, Bridge strings, dead routes, an activation race and undelivered results (#4406, #4407); startup no longer fails when the DBS sample type is missing (#4413).

  • Administration and navigation. Saving a result select list shows the correct notification (#4320); home dashboard paging is corrected (#4302, superseded by server-driven paging in #4405); side navigation groups stay open when a menu item's route redirects (#4427).

Security

  • Trivy image scans, SBOM generation and image security artifacts in the release workflows (#3952).

  • Role-based access control on every cold-storage and alert endpoint, with attribution taken from the signed-in session (#3828).

  • Database and FHIR runtime images moved off Debian Bullseye, which is end of life (#4225).

Internationalization

  • Language bundles are discovered automatically, so every translation pulled from Transifex is selectable; locale codes are matched whatever their spelling (fr_MG, fr-MG), and a regional variant falls back to its base language before English (#4155).

  • Ongoing translation updates from Transifex throughout the release cycle, plus a fix that unblocked the Transifex push (#4419).

Developer & infrastructure

  • A deterministic backend test suite, with fixes to the tests it exposed (#4324), stronger assertions across catalog, dictionary, label preset and core service tests (#4349, #4350, #4351), and new integration tests for sample orders, status, add-test and the sample REST controller.

  • Analyzer harness coverage for non-ASCII GeneXpert data (#4143); the analyzer bridge pinned to release 3.2.1 (#4404).

  • Deployments gated on existing-data upgrades (#4255); image publishing restored (#4200); E2E skipped for documentation-only pull requests (#4387).

  • Community issue templates (#3928), build warning cleanup (#2935) and backend integration testing skills (#3578).

Configuration & upgrade notes

  • Back up before upgrading. Database migrations run automatically on first start. A 3.2.2.0 database upgrades in place; the fixes that make this possible for real 3.2.2.0 data (critical-result alerts, analyses without a sample item, a QC lot on two instruments, lagging sequences and analyzer data) are in #4431 and #4432.

  • Existing analyzers are migrated to the Analyzer Bridge after startup, keeping analyzer IDs, clinical history, settings and test mappings (#4433). An interrupted transfer resumes; an incomplete or conflicting configuration stays visibly pending with a retry action. Operators still confirm mappings and activate analyzers.

  • Database image: PostgreSQL 14.4 → 14.24 on Debian Bookworm (#4225). This is a minor upgrade in place, with no dump or pg_upgrade. Because the operating system's collation library changes, the image rebuilds text indexes online, once, on the first start against an existing volume; start-up is not held and nothing is locked. Set OE_DB_SKIP_COLLATION_REINDEX=true to skip this and rebuild in a maintenance window instead (see docs/service-image-maintenance.md). The FHIR image runs the same HAPI 6.6.0 on a new runtime, and an existing server.xml mount keeps working.

  • Unified Results Entry is now the default (#4209). Legacy "By Patient" links forward to the unified page's patient search.

  • Programmes are assigned the Clinical domain on upgrade (#3979). The Environmental and Vector programme pickers stay empty until an administrator reclassifies the relevant programmes.

  • The FHIR store is optional for programme questionnaires and facade searches (#4205, #4223). When org.openelisglobal.fhirstore.uri is set, questionnaires are still mirrored to it, and questionnaires held only in the store are copied locally on first read.

  • Pathology status values are mapped onto the new bench stages on upgrade; the retired names (Cutting, Slicing, Additional Request) cannot be restored by rollback (#4298). Optional stages can be switched off on Result Entry Configuration.

  • Test catalog CSV files (#4327, #4329) now load on every restart, one row at a time: a rejected row is skipped with its line number and reason while the rest of the file loads. Tests an earlier loader created as Name(SampleType) are recognised and updated in place rather than duplicated. New optional tests.csv columns include isReportable, notifyResults, localCode, reportingName, domain and amr.

  • Inventory lot locations move into the sample storage system (#4016); existing storage assignment rows are backfilled as sample occupants.

New contributors

Welcome to @WodPachua, who made their first contribution in this release.

For the complete commit-level list, see the GitHub release notes.