Add a test to the test catalogue
doc-verified + verified-v 3.3.0
How-to · Lab administrators
Part of: Test Catalog Management — workflow overview
Status: draft, unverified against 3.2.2.0. Verification is tracked on OGC-1212.
At a glance
Purpose | Define a new test so it can be ordered and results recorded against it. |
|---|---|
You'll end up with | An active, orderable test in the catalogue. |
Who does this | Lab administrators. Access is set by user permissions and can be configured by your administrator. |
Before you start | The test name and the code your laboratory uses, the laboratory unit that performs it, and every specimen type it runs on. |
Where | Main menu → Admin Management → Test Catalogue Management → Test Catalogue Editor |
Adding a test happens in two stages
First you create the test. It records the name, code, laboratory unit and specimen types, and it is created inactive — nobody can order it yet.
Then you configure its sections and set it active. This is what makes it orderable.
The two stages are deliberate. They let you finish configuring a test before clinicians can order it, so nobody orders something that is only half set up.
Open the test catalogue
The Test Catalog page lists every test defined, with its sample type, code, domain and status.
A banner may report that a number of tests have configuration issues, split into errors and warnings. This describes the catalogue as a whole, not anything you have just done.
Create the test
Select New test. The button sits to the right of the search box.
The Create new test form opens on its Basic Info section.
Enter the test name and reporting name. Test name is the full name your laboratory uses. Reporting name is the shorter form that appears on reports.
Enter the test code. Clear the field before typing. The code is filled in automatically from the test name as you type it, so typing into the field without clearing it first appends your code to the name instead of replacing it.
Choose the Lab Unit. Select the laboratory unit that performs the test. This list does not narrow as you type, so scroll to find the entry. Note that some units use American spellings — haematology appears as Hematology.
Choose the sample types. Select every specimen the test runs on. This list does narrow as you type. At least one is required and Save will not proceed without one. Configuration is shared across all the sample types you select, so a test running on several specimens is configured once. Each selection appears as a chip beneath the field with a cross to remove it.
Set the domain. Clinical, Environmental or Vector. Clinical is selected by default.
Set the remaining options. AMR surveillance test marks the test as contributing to antimicrobial resistance surveillance. Orderable controls whether clinicians can order it. Both default to No. Description is optional free text.
Select Save. The form reopens as an edit view with the test name in the page heading and the full list of configuration sections in the Main menu. The test is now inactive.
Two things change once the test is saved: the field labels shift from Test name and Test code to Name and Code, and the form gains two settings the create form did not have, Culture workflow and Active.
Configure and activate
The sections that make up a test are Basic Info, Sample & Results, Methods, Ranges, Sample Storage, Panels, Labels, Terminology, Reagents, Analyzers, Alerts, Reflex & Calc, Localization and Display Order. Each has its own page — see the workflow overview.
At minimum, set up Sample & Results so the test has a result type. A test with no result type selected cannot have results entered against it.
Return to Basic Info and set Active to Yes. Scroll to the foot of Basic Info. Set Active to Yes, and set Orderable to Yes if clinicians should be able to order the test.
Select Save.
Confirm the test appears in the catalogue. Return to the Test Catalog list and search for it by name. It should show a status of Active.
Tips
Clear the Test code field before typing, or the code is appended to the auto-filled test name.
The Lab Unit list does not filter as you type. Scroll instead. The Unit of measure list in Sample & Results behaves the same way; the Sample types list does filter.
A test cannot be saved without at least one sample type. The form blocks it with "Select at least one sample type."
If a newly created test does not appear to clinicians, check Active on Basic Info before assuming something is broken. Tests are created inactive by design.
What's next: Edit a test's Basic Info · Configure Sample & Results · Set ranges.
Provenance
Status | Draft, unverified |
|---|---|
Feature Doc | OGC-1203 |
Instance | Local develop stack, OpenELIS 3.2.2.0 |
Worked example | Haemoglobin Electrophoresis (HPLC), code HBELP, test id 993 |
Drafted | 11 September 2026 |
Reviewer | Pending — OGC-1212 |