Configure a test's sample types & result components
Part of: Test Catalog Management — workflow overview
How-to · Lab administrators
At a glance
Purpose | Define how a test's results are captured — components, type, unit. |
|---|---|
You'll end up with | A test with its result component(s) configured. |
Who does this | Lab administrators. Access is set by user permissions and can be configured by your administrator. |
Before you start | The test exists; units of measure are configured. |
Where | Main menu → Admin Management → Test Catalogue Management → Test Catalogue Editor → your test → Sample & Results. |
How components work
Most tests record a single result. Where a test records several — a differential, a set of fractions, a group of readings taken together — each value is a result component.
Every test has one component from the moment it is created, called the primary component. You do not create it and you cannot remove it. Any further components are added alongside it.
The primary component differs from the others in three ways: its code is fixed at PRIMARY, its Show on patient report setting cannot be changed, and its label is filled in from the test name when the test is created.
Open Sample & Results
Existing components are listed as collapsed bars showing the component label, its code and its result type. A bar reading "No result type selected" means that component cannot yet have results entered against it.
Configure the primary component
Expand the primary component. It is the one whose code is
PRIMARYand whose Primary component setting is Yes.Set the Component label. It arrives filled in from the test name; change it to describe what this particular value is, rather than the test as a whole.
Choose the Result type: Numeric (a measured number with a unit), Single-select list (dictionary) (one value from a fixed set), or Free text. An Advanced / legacy types link offers further options.
For a single-select component, add options under Select-list options. Use Add custom option, or search the dictionary to reuse an existing value. Each row has a Value, a Sort order and a Normal checkbox; options appear in ascending sort order. Tick Normal on the option representing a normal result.
Add value-based Interpretations (value match → interpretation → severity) where needed.
Add further components
Click Add component, at the foot of the section beside Save. Remove one with Remove component.
Enter a Component code and Component label. Unlike the primary component, the code is yours to set.
Choose the result type. For a numeric component a Unit of measure list appears; it does not narrow as you type, so scroll to find the unit. Significant digits controls rounding — leave blank for none.
On components you add, Show on patient report is available and defaults to Yes. Set it to No for a value recorded internally that should not appear on the patient's report.
Click Save. To copy another test's setup, use Copy configuration from test.
Check what the technician will see
Each component carries a Result entry preview showing how that result will appear during result entry. It updates as you change the result type and unit, so you can confirm a component is set up correctly without leaving the page.
Order the components
Each component has a Display order value, and the up and down arrows at the top of an expanded component move it relative to its neighbours. Components appear during result entry in this order.
Tips
The primary component always exists. If you are looking for a way to create it, there isn't one — relabel it instead.
Collapse the component bars to see the whole structure of a multi-component test at a glance.
A single-select component with no options defined cannot have results entered against it. The section warns when options are missing.
Neither the Unit of measure list nor the Lab Unit list narrows as you type.
Not yet documented
Default result and Allow multiple readings appear in the section but have not been exercised. Reference ranges are configured in the Ranges section and are covered separately.
What's next: Set ranges · Link methods.