Identify vector species & deconvolute a pool
Part of: Vector Surveillance — workflow overview
How-to · Analyst · Vector
At a glance
Purpose | Identify the species of each specimen in a submitted pool and, if needed, split the pool to localize a carrier specimen. |
|---|---|
You'll end up with | Specimens identified by species, and (optionally) sub-pools created for further testing. |
Who does this | Analyst. Access is set by user permissions and can be configured by your administrator. |
Before you start | A submitted vector order; the species list configured (see Admin — Vector Surveillance Reference Data). |
Where | Main menu → Results → Vector Identification. |
Identify a specimen
Open Results → Vector Identification. Submitted pools appear automatically; expand the lot (e.g. DEV…021-P01) to see the Species Distribution bar and the per-specimen table.
On a specimen row click to expand then select checkbox then click Identify.
Set Species (type-ahead), Method (Morphological / Molecular / both), and Confidence (Confirmed / Presumptive); optional Lifecycle Stage + Notes. Click Save Identification — the Species Distribution and progress counter update.
Deconvolute (split into sub-pools)
On the pool row click ↗ Split.
Set How many pools? (or Split to individuals) and an Assignment method (random / auto by species / manual); tick the tests for sub-pools.
Click Preview Grouping and review the proposed sub-pools.
Click Save Pools — sub-pools are created (e.g. P01-S1 … P01-S5), each independently splittable; identified specimens carry their species into the sub-pool.
Note: the split success toast may read “25 sub-pools (null–null)” — cosmetic only; the real result is the sub-pools shown in the preview.