Enter a vector order

Enter a vector order

Part of: Vector Surveillance — workflow overview

How-to · Field/Lab staff · Vector

At a glance

Purpose

Register a pooled field collection of organisms (mosquitoes, larvae, fleas, rodents) and submit it for testing.

You'll end up with

A submitted vector order whose pool is tracked as per-specimen barcodes, ready for species identification.

Who does this

Field / lab staff. Access is set by user permissions and can be configured by your administrator.

Before you start

The sampling site, species list, and trap types must be configured (see Admin — Vector Surveillance Reference Data).

Where

Main menu → Order → Add Vector Order → Enter Order.

Overview

A vector order is organism-based: instead of a patient you record the organism type, the trap it came from, and how many specimens are in the pool. On save, the pool is tracked as individual specimen barcodes. This page covers building and submitting the order; identifying species and deconvoluting the pool are separate tasks (see What’s next).

Enter the order

  1. Open Main menu → Order → Add Vector Order

Add vector order
Add vector order
  1. Open→ Enter Order, click Generate Lab Number,

Generate lab number
Generate lab number
  1. Set the Sampling Site ( WS-001 / MULAGO).

Search and select
Search and select

 

  1. Under Animal / Organism 1, choose the Sample Type (e.g. Adult Mosquito). Set Lifecycle Stage, Trap Type, and Quantity in Pool (e.g. 25). Open Tests & Panels and tick at least one test (e.g. Wolbachia sp.).

File in sample
File in sample

 

Warning: the order will not save without at least one test. If you see “add a patient or sampling site”, the field actually missing is the test.

  1. Click Save & Next. The pool expands to one barcode per specimen (LABNO.2 … LABNO.26 for a pool of 25).

Save & Next
Save & Next

Label & store the specimens

This stage is the same for every order type:

Steps

  1. Click on print labels to print specimen labels

  2. Assign storage location. or tick skip storage for now-both are optional

  3. Click save & next to continue to QA Review

Label & store
Label & store

 

Complete QA review

Then complete QA review and submit — the pool is then ready for species identification:

  1. Complete the Sample Acceptance Checklist - manual Pass/ Fail/NA per item - where your domain’s enforcement is Mandatory or Optional

  2. Click Submit. The order is submitted and completed

Complete QA process
Complete QA process

Complete

1. Click on complete

Complete order entry
Complete order entry

Field reference

Sampling Site

The vector “patient” — where the collection came from (e.g. WS-001 / MULAGO). Required.

Sample Type

Organism type from the taxonomy (e.g. Adult Mosquito). Drives Trap Type + Quantity in Pool.

Trap Type

The trap the specimens came from (configured in admin).

Quantity in Pool

Number of specimens (e.g. 25) — expands to per-specimen barcodes on save.

Tests & Panels

At least one test required, or the order will not save.

Tips & notes

  • Per-specimen barcodes run LABNO.2 … (the .1 is the order/pool).

  • Species, trap types, and sampling sites are configured by an administrator — see Admin — Vector Surveillance Reference Data.

What’s next

  • Identify vector species & deconvolute a pool