Enter a vector order
Part of: Vector Surveillance — workflow overview
How-to · Field/Lab staff · Vector
At a glance
Purpose | Register a pooled field collection of organisms (mosquitoes, larvae, fleas, rodents) and submit it for testing. |
|---|---|
You'll end up with | A submitted vector order whose pool is tracked as per-specimen barcodes, ready for species identification. |
Who does this | Field / lab staff. Access is set by user permissions and can be configured by your administrator. |
Before you start | The sampling site, species list, and trap types must be configured (see Admin — Vector Surveillance Reference Data). |
Where | Main menu → Order → Add Vector Order → Enter Order. |
Overview
A vector order is organism-based: instead of a patient you record the organism type, the trap it came from, and how many specimens are in the pool. On save, the pool is tracked as individual specimen barcodes. This page covers building and submitting the order; identifying species and deconvoluting the pool are separate tasks (see What’s next).
Enter the order
Open Main menu → Order → Add Vector Order
Open→ Enter Order, click Generate Lab Number,
Set the Sampling Site ( WS-001 / MULAGO).
Under Animal / Organism 1, choose the Sample Type (e.g. Adult Mosquito). Set Lifecycle Stage, Trap Type, and Quantity in Pool (e.g. 25). Open Tests & Panels and tick at least one test (e.g. Wolbachia sp.).
Warning: the order will not save without at least one test. If you see “add a patient or sampling site”, the field actually missing is the test.
Click Save & Next. The pool expands to one barcode per specimen (LABNO.2 … LABNO.26 for a pool of 25).
Label & store the specimens
This stage is the same for every order type:
Steps
Click on print labels to print specimen labels
Assign storage location. or tick skip storage for now-both are optional
Click save & next to continue to QA Review
Complete QA review
Then complete QA review and submit — the pool is then ready for species identification:
Complete the Sample Acceptance Checklist - manual Pass/ Fail/NA per item - where your domain’s enforcement is Mandatory or Optional
Click Submit. The order is submitted and completed
Complete
1. Click on complete
Field reference
Sampling Site | The vector “patient” — where the collection came from (e.g. WS-001 / MULAGO). Required. |
|---|---|
Sample Type | Organism type from the taxonomy (e.g. Adult Mosquito). Drives Trap Type + Quantity in Pool. |
Trap Type | The trap the specimens came from (configured in admin). |
Quantity in Pool | Number of specimens (e.g. 25) — expands to per-specimen barcodes on save. |
Tests & Panels | At least one test required, or the order will not save. |
Tips & notes
Per-specimen barcodes run LABNO.2 … (the .1 is the order/pool).
Species, trap types, and sampling sites are configured by an administrator — see Admin — Vector Surveillance Reference Data.
What’s next
Identify vector species & deconvolute a pool